Process Equipment and Plant Design With increase in pressure drop (for a given particle size), the dust collection efficiency of a cyclone separator will Remain unaffected Increase Decrease Increase or decrease depending on the nature of the dust Remain unaffected Increase Decrease Increase or decrease depending on the nature of the dust ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Bubble cap tray is the most commonly used tray in large distillation column, because None of these Of its flexibility and nearly constant efficiency under varying conditions of operation It incurs less pressure drop as compared to any other try designed for the same duty It eliminates the foaming and entrain-ment tendency during operation None of these Of its flexibility and nearly constant efficiency under varying conditions of operation It incurs less pressure drop as compared to any other try designed for the same duty It eliminates the foaming and entrain-ment tendency during operation ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Le/D for a Tee (used as elbow, entering run) would be around 5 200 60 350 5 200 60 350 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The testing pressure of storage tanks and pressure vessels designed as per Indian standard codes should be about __________ times.the design pressure. >5 3 to 4 4 to 5 1.5 to 2 >5 3 to 4 4 to 5 1.5 to 2 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Heat transfer co-efficient, hG(Kcal/hr.m² .°C) and mass velocity of air, G (kg/hr.m² ) for air flow parallel to the surface in case of constant drying rate in batch drying is related as hG = 0.0176G0.8. But when the flow of air perpendicular to the surface is encountered, this equation changes to 1.004G0.8 0.0176G1.37 HG = 1.004G0.37 HG = 0.0176G0.37 1.004G0.8 0.0176G1.37 HG = 1.004G0.37 HG = 0.0176G0.37 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Vertical condenser is advantageous to the horizontal condenser from operation point of view, when Only the function of condensation is to be carried out Both the functions of condensation & sub cooling are carried out in a single unit Sub cooling of condensate is desired Hydrostatic head is required for refluxing the condensate Only the function of condensation is to be carried out Both the functions of condensation & sub cooling are carried out in a single unit Sub cooling of condensate is desired Hydrostatic head is required for refluxing the condensate ANSWER DOWNLOAD EXAMIANS APP