Power Systems The advantage of hydro electric power station over thermal power station is hydro electric station can be constructed at the place where the energy is required the initial cost of hydro electric power station is low hydro electric power station can supply the power throughout the year the operation cost of hydro electric power station is low hydro electric station can be constructed at the place where the energy is required the initial cost of hydro electric power station is low hydro electric power station can supply the power throughout the year the operation cost of hydro electric power station is low ANSWER DOWNLOAD EXAMIANS APP
Power Systems Three generators rated 100 MVA, 11 kV have an impedance of 0.15 pu each. If in the same plant, these generators are being replaced by a single equivalent generator, the effective impedance of equivalent generator will be 0.15 pu 0.45 pu 0.05 pu 0.25 pu 0.15 pu 0.45 pu 0.05 pu 0.25 pu ANSWER DOWNLOAD EXAMIANS APP
Power Systems Which of the following contributes to the Rankine cycle efficiency improvement in a thermal power plant All of these Use of steam for heating of boiler feed water. Use of high pressure. Reheat of steam an intermediate stages. All of these Use of steam for heating of boiler feed water. Use of high pressure. Reheat of steam an intermediate stages. ANSWER DOWNLOAD EXAMIANS APP
Power Systems A lossless power system has to serve a load of 250 MW. There are two generators(G1 and G2) in the system with cost curves C1 and C2 respectively defined as follows: C1 = PG1+0.055P²G1 C2 = 3 PG2 + 0.03 P²G2 Where PG1 and PG2 are the MW injections from generators G1 and G2 respectively. Thus, the minimum cost dispatch will be PG1 = 150 MW and PG2 = 100 MW PG1 = 100 MW and PG2 = 150 MW PG1 = 250 MW and PG2 = 0 MW PG1 = 0 MW and PG2 = 250 MW PG1 = 150 MW and PG2 = 100 MW PG1 = 100 MW and PG2 = 150 MW PG1 = 250 MW and PG2 = 0 MW PG1 = 0 MW and PG2 = 250 MW ANSWER DOWNLOAD EXAMIANS APP
Power Systems How to find the total number of strands (N) when number of layers (x) are given Total number of strands N = 3x² - 3x - 1 Total number of strands N = 3x² + 3x + 1 Total number of strands N = 3x² - 3x + 1 Total number of strands N = 3x² + 3x - 1 Total number of strands N = 3x² - 3x - 1 Total number of strands N = 3x² + 3x + 1 Total number of strands N = 3x² - 3x + 1 Total number of strands N = 3x² + 3x - 1 ANSWER DOWNLOAD EXAMIANS APP
Power Systems A 50 Hz, 17.32 kV generator is connected to a power system. The system reactance and capacitance per phase are 10 mH and 0.2 mF respectively. What is the maximum voltage across the contacts of the circuit breaker at an instant when it passes through zero? 28.28 kV 29.28 kV 31.28 kV 30.28 kV 28.28 kV 29.28 kV 31.28 kV 30.28 kV ANSWER DOWNLOAD EXAMIANS APP