Power Systems The Y bus matrix of a 100 bus interconnected system is 90% sparse. Then find the number of non zero elements in the Y bus matrix? 90 1000 9000 10 90 1000 9000 10 ANSWER DOWNLOAD EXAMIANS APP
Power Systems The load duration curve for a system is 8 hours 30 MW, 16 hours 25 MW and 24 hours 20 MW. The load factor will be 0.44. 0.25. 1.3. 0.83. 0.44. 0.25. 1.3. 0.83. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The surge impedance of a 400 km long overhead transmission line is 420 Ω. For a 200 km length of the same line, the surge impedance will be 840 Ω 420 Ω 210 Ω 400 Ω 840 Ω 420 Ω 210 Ω 400 Ω ANSWER DOWNLOAD EXAMIANS APP
Power Systems In a pressurized water reactor the coolant water boils in the reactor core. water is used at high pressure so that it is available is liquid from at about 280° C. heavy water is used as both coolant and moderator. both B and C. the coolant water boils in the reactor core. water is used at high pressure so that it is available is liquid from at about 280° C. heavy water is used as both coolant and moderator. both B and C. ANSWER DOWNLOAD EXAMIANS APP
Power Systems To protect the power transformer ( Y-Y with neutral grounded) against fault, which type of connection do the current transformers have? Y-Δ connection Δ-Y connection Y-Y connection Δ-Δ connection Y-Δ connection Δ-Y connection Y-Y connection Δ-Δ connection ANSWER DOWNLOAD EXAMIANS APP
Power Systems A penstock is used as a condition between the turbine and discharge drain. none of above. the dam and the turbine in a hydro station. the heat ex-changer and the turbine in nuclear power plant. the turbine and discharge drain. none of above. the dam and the turbine in a hydro station. the heat ex-changer and the turbine in nuclear power plant. ANSWER DOWNLOAD EXAMIANS APP