Measurement and Instrumentation The total current I = I1 + I2 in a circuit is measured I1 = 150 ± 3A , I2 = 250 ± 4 A, where the limits of error are given as standard deviations. I is measured as (400 ± 2.24) A (400 ± 3) A (400 ±5) A (400 ± 1) A (400 ± 2.24) A (400 ± 3) A (400 ±5) A (400 ± 1) A ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The limiting errors of measurement of power consumed by and the current passing through a resistance are ±1.5% and ±1% respectively. What is the limiting error ( in %) of measurement of resistance ? ± 1.5% ± 1% ±3.5% ± 2.5% ± 1.5% ± 1% ±3.5% ± 2.5% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The pressure coil of a wattmeter should be connected on the supply side of the current coil when None of these Load impedance is low Supply voltage is low Load impedance is high None of these Load impedance is low Supply voltage is low Load impedance is high ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A metal strain gauge has a gauge factor of two. Its nominal resistance is 120 ohms. If it undergoes a strain of 10-5, the value of change of resistance in response to the strain is 240 Ohm. 0.0012 Ohm. 120 Ohm. 0.0024 Ohm. 240 Ohm. 0.0012 Ohm. 120 Ohm. 0.0024 Ohm. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A DC potentiometer is designed to measure up to about 2V with a slide wire of 800 mm. A standard cell of emf 1.18 V obtains balances at 600 mm. A test cell is seen to obtain balance at 680 mm. The emf of test cell is 1.7 V. 1.5 V. 1.34 V. 1 V. 1.7 V. 1.5 V. 1.34 V. 1 V. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The use of thermocouple meters for AC measurement leads to scale which is logarithmic. square law. expontial. linear. logarithmic. square law. expontial. linear. ANSWER DOWNLOAD EXAMIANS APP