Electrical Machines The current drawn by the armature of DC motor is directly proportional to The speed of motor. None of above. The torque required. The voltage across the terminals. The speed of motor. None of above. The torque required. The voltage across the terminals. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Consider the following statements about commutating poles which are fitted on most large dc Shunt motors: 1. The commutating poles are placed in the geometric neutral plane and their number is usually Equal to the number of main poles 2. The winding on the commutating poles is connected in series with the shunt-field winding on the main poles 3. The polarity of the commutating pole must be that of the next pole further ahead 4. The commutating poles neutralize the reactance voltage produced in the coil undergoing Commutation. Of these statements, 1 and 4 are correct 2, 3 and 4 are correct 1, 2 and 4 are correct 1, 2 and 3 are correct 1 and 4 are correct 2, 3 and 4 are correct 1, 2 and 4 are correct 1, 2 and 3 are correct ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A 500 V, 55 kVA single phase alternator has an effective resistance of 0.5 Ω. An excitation current of 10 A produces 200 A armature current on short circuit and an emf of 450 V on per circuit. The synchronous reactance will be 25.564 Ω. 2.241 Ω. 2.74 Ω. 2.781 Ω. 25.564 Ω. 2.241 Ω. 2.74 Ω. 2.781 Ω. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines The leakage reactance of a 3-phase alternator is determined by performing short circuit and slip tests. open circuit and zero power factor tests. open circuit and short circuit tests. zero power factor and slip tests. short circuit and slip tests. open circuit and zero power factor tests. open circuit and short circuit tests. zero power factor and slip tests. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Two generators operating in parallel with rating 50MW and 100MW respectively. Both their respective governor settings are identical as 4%, consider same no load frequency. How will the machine share a common load of 100 MW 50 MW and 50 MW respectively 33.33 MW and 66.67 MW respectively any of the above 66.67 MW and 33.33 MW respectively 50 MW and 50 MW respectively 33.33 MW and 66.67 MW respectively any of the above 66.67 MW and 33.33 MW respectively ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines What is the reason for stationary armature essential in alternators above 5 KVA? Collecting of large current is simple. Insulation requirement is less. All of these Operating cost is less. Collecting of large current is simple. Insulation requirement is less. All of these Operating cost is less. ANSWER DOWNLOAD EXAMIANS APP