Building Construction In grillage foundations, distance between flanges of grillage beams, is kept Equal to flange width 40 cm Twice the flange width Maximum of (A), (B) and (C) Equal to flange width 40 cm Twice the flange width Maximum of (A), (B) and (C) ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: Area of footing slab = 11.00 m2 All listed here Distance of C.G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m Area of footing slab = 11.00 m2 All listed here Distance of C.G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m ANSWER DOWNLOAD EXAMIANS APP
Building Construction Two columns 50 cm × 50 cm and 60 cm × 60 cm carry 80 tonnes and 120 tonnes of loads respectively. The centre to centre distance between columns is 5.00 metres. The permissible bearing capacity of the soil is 20 t/m2. If the footing is not to project more than 25 cm beyond the outside of the smaller column, pick up the correct design parameters of the footing from the following: Area of footing slab = 11.00 m2 Distance of G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m All listed here Area of footing slab = 11.00 m2 Distance of G. of the loads from the smaller column = 3.00 m The length of the foundation slab = 7.00 m All listed here ANSWER DOWNLOAD EXAMIANS APP
Building Construction The lower half portion between crown and skew back of the arch, is called Haunch Springing Soffit Spandril Haunch Springing Soffit Spandril ANSWER DOWNLOAD EXAMIANS APP
Building Construction Raft foundations are used for: Spanning over small soft or loose pockets Counter acting the hydrostatic effect Providing increased area of foundation over poor bearing capacity of soil All listed here Spanning over small soft or loose pockets Counter acting the hydrostatic effect Providing increased area of foundation over poor bearing capacity of soil All listed here ANSWER DOWNLOAD EXAMIANS APP
Building Construction In soft clay of low bearing capacity, the type of steel pile generally used, is H-pile Disc pile Screw pile Pipe pile H-pile Disc pile Screw pile Pipe pile ANSWER DOWNLOAD EXAMIANS APP