Power Systems A 3-phase transmission line operating at Vs = 400 kV and has ABCD parameters A= D = 0.8∠0°, B = 100∠90° Ω, C = 0.5*10-6∠90° â„§. Find the no load receiving end voltage? 600 kV 320 kv 500 kV 400 kV 600 kV 320 kv 500 kV 400 kV ANSWER DOWNLOAD EXAMIANS APP
Power Systems The sequence components of the fault current are as follows : Ipositive = j1.5 pu, Inegative = − j0.5 pu, Izero = − j pu Which fault is this? LLLG. LG. LLG. LL. LLLG. LG. LLG. LL. ANSWER DOWNLOAD EXAMIANS APP
Power Systems If the rated receiving end voltage is 33 kV, then what are the limits for safe operation of equipments? 31.35 to 34.65 kV 33 to 50 kV 25 to 35 kV any voltage above 33 kV 31.35 to 34.65 kV 33 to 50 kV 25 to 35 kV any voltage above 33 kV ANSWER DOWNLOAD EXAMIANS APP
Power Systems Keeping in view the cost and overall effectiveness, the following circuit breaker is suited for capacitor bank switching air blast. SF6. vacuum. oil. air blast. SF6. vacuum. oil. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The rate of rise of restricting voltage depends upon the Inductance of the system. Type of CB. Inductance and capacitance of the system. Capacitance of the system. Inductance of the system. Type of CB. Inductance and capacitance of the system. Capacitance of the system. ANSWER DOWNLOAD EXAMIANS APP
Power Systems An hydro-graph indicates the discharge at any time during the period under consideration. the maximum and minimum run off during the period. the average run off during the period. All of these the discharge at any time during the period under consideration. the maximum and minimum run off during the period. the average run off during the period. All of these ANSWER DOWNLOAD EXAMIANS APP