Gas Chromatography What are the benefits of decreasing the column internal diameter? Increased resolution Reduced risk of column overloading All of these Increased sample capacity Increased resolution Reduced risk of column overloading All of these Increased sample capacity ANSWER DOWNLOAD EXAMIANS APP
Gas Chromatography A retention gap is placed between the injector and the front of the column to prevent backflush of the injected solution retain contaminants and prevent them from reaching the column All of these retain the sample and release it gradually to the column prevent backflush of the injected solution retain contaminants and prevent them from reaching the column All of these retain the sample and release it gradually to the column ANSWER DOWNLOAD EXAMIANS APP
Gas Chromatography Split injection is carried out by splitting the sample into smaller portions to inject sequentially splitting the sample into smaller portions to inject at the same time through parallel ports None of these splitting off some of the sample so that it does not enter the column splitting the sample into smaller portions to inject sequentially splitting the sample into smaller portions to inject at the same time through parallel ports None of these splitting off some of the sample so that it does not enter the column ANSWER DOWNLOAD EXAMIANS APP
Gas Chromatography What does the selectivity factor describe? The relative separation achieved between two species The proportional difference in widths of two chromatographic peaks None of these The maximum number of different species which a column can separate simultaneously The relative separation achieved between two species The proportional difference in widths of two chromatographic peaks None of these The maximum number of different species which a column can separate simultaneously ANSWER DOWNLOAD EXAMIANS APP
Gas Chromatography Column bleeding occurs when the column is cracked and stationary phase leaks out traces of the stationary phase are eluted the column breaks during installation and causes personal injury elution of the analyte is extended over time the column is cracked and stationary phase leaks out traces of the stationary phase are eluted the column breaks during installation and causes personal injury elution of the analyte is extended over time ANSWER DOWNLOAD EXAMIANS APP
Gas Chromatography Which of the following detectors give mass flow-dependent signals? Electron capture detector Field ionisation detector Thermal conductivity detector All of these Electron capture detector Field ionisation detector Thermal conductivity detector All of these ANSWER DOWNLOAD EXAMIANS APP