Water Supply Engineering In pressure supply mains, water hammer pressure is reduced by providing Sluice valves None of these Air valves Pressure relief valves Sluice valves None of these Air valves Pressure relief valves ANSWER DOWNLOAD EXAMIANS APP
Water Supply Engineering In centrifugal pump installation, The diameter of the pipe at inlet as well as at outlet, is kept smaller than the delivery pipe All listed here The motor may burn out if it is started with empty delivery pipe and with open gate valve Pump is properly primed before starting The diameter of the pipe at inlet as well as at outlet, is kept smaller than the delivery pipe All listed here The motor may burn out if it is started with empty delivery pipe and with open gate valve Pump is properly primed before starting ANSWER DOWNLOAD EXAMIANS APP
Water Supply Engineering The yield of a rapid gravity filter as compared to that of slow sand filter, is 30 times 20 times 15 times 10 times 30 times 20 times 15 times 10 times ANSWER DOWNLOAD EXAMIANS APP
Water Supply Engineering To pump water from a water reservoir 3 m deep and maximum water level at 135 m, a pump is installed to lift water up to R.L. 175 m at a constant rate of 36,00,000 litres per hour. If the length of the pipe is 1506 m and f = 0.01, ignoring other minor losses and assuming the economical diameter from Lea's formula D = 1.2 √Q, the water horse power of the pump is 500 400 450 600 500 400 450 600 ANSWER DOWNLOAD EXAMIANS APP