Mass Transfer The relative humidity of air decreases in-spite of an increase in the absolute humidity, when the Pressure rises Pressure falls Temperature rises Temperature falls Pressure rises Pressure falls Temperature rises Temperature falls ANSWER DOWNLOAD EXAMIANS APP
Mass Transfer For a single component absorber, the operating line is straight only when plotted in term of __________ units. Mole ratio None of these Partial pressure Mole fraction Mole ratio None of these Partial pressure Mole fraction ANSWER DOWNLOAD EXAMIANS APP
Mass Transfer In an operating distillation column, the Highest temperature is encountered at the top of the column Vapors and liquids are at their dew point and bubble point respectively Driving force for the liquid flow is its specific weight Driving force for the vapor flow is the pressure drop, as the pressure decreases gradually from the bottom to the top of the column Highest temperature is encountered at the top of the column Vapors and liquids are at their dew point and bubble point respectively Driving force for the liquid flow is its specific weight Driving force for the vapor flow is the pressure drop, as the pressure decreases gradually from the bottom to the top of the column ANSWER DOWNLOAD EXAMIANS APP
Mass Transfer Compound A is extracted from a solution of A + B into a pure solvent S. A Co-current unit is used for the liquid-liquid extraction. The inlet rate of the solution containing A is 200 moles of B/hr.m² and the solvent flow, rate is 400 moles of S/m². hr. The equilibrium data is represented by Y = 3X² , where Y is in moles of a A/moles of B and X is in moles A/moles of S. The maximum percentage extraction achieved in the unit is 0.7 0.9 0.5 0.25 0.7 0.9 0.5 0.25 ANSWER DOWNLOAD EXAMIANS APP
Mass Transfer Experiments were conducted to determine the flux of a species A in a stagnant medium across a gas-liquid interface. The overall mass transfer co-efficient based on the liquid side for dilute systems for the above was estimated to be 4 x 10⁻³ kg mole/m².s. The equilibrium data for the system is given as y = 2x. The flux across the interface (in kg mole/m² .s) for bulk concentrations of A in gas phase and liquid phase as y = 0.4 and x = 0.01 respectively is 8.5 x 10⁻³ 5.6 x 10⁻⁴ 8.5 x 10⁻⁴ 5.6 x 10⁻³ 8.5 x 10⁻³ 5.6 x 10⁻⁴ 8.5 x 10⁻⁴ 5.6 x 10⁻³ ANSWER DOWNLOAD EXAMIANS APP
Mass Transfer To remove all the moisture from a wet solid it requires exposure to __________ air. Perfectly dry High temperature Highly humid None of these Perfectly dry High temperature Highly humid None of these ANSWER DOWNLOAD EXAMIANS APP