Process Equipment and Plant Design The length of straight rectangular weir used on cross-flow trays is generally __________ the column diameter. 2 ft irrespective of (for column > 3 ft diameter) Equal to 0.6-0.8 times Twice 2 ft irrespective of (for column > 3 ft diameter) Equal to 0.6-0.8 times Twice ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Pick out the wrong statement pertaining to the design of the distillation column. If sufficient slot area is not provided, the gas may pass through the skirt clearance None of these The purpose of the slot is to disperse the gas into the liquid in the form of small bubbles Generally, a skirt clerance of 0.5" to 1.5' is recommended to prevent plugging of the slots by residue build up If sufficient slot area is not provided, the gas may pass through the skirt clearance None of these The purpose of the slot is to disperse the gas into the liquid in the form of small bubbles Generally, a skirt clerance of 0.5" to 1.5' is recommended to prevent plugging of the slots by residue build up ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The buckling tendency of compression members is always in the direction of the Axis of the load Least radius of gyration None of these Perpendicular to the axis of the load Axis of the load Least radius of gyration None of these Perpendicular to the axis of the load ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design If 'D' is the inside diameter of the shell of a shell and tube heat exchanger, then the baffle spacing is usually in the range of D/5 or minimum 2" to D D/2 or minimum 2" to 5D None of these D/5 or minimum 2" to 5D D/5 or minimum 2" to D D/2 or minimum 2" to 5D None of these D/5 or minimum 2" to 5D ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Floating head heat exchangers are used for the Cases where temperature difference between the shell and the tubes is more (>50°C) Counter-current heat transfer systems Heat transfer between corrosive fluids Co-current heat transfer systems Cases where temperature difference between the shell and the tubes is more (>50°C) Counter-current heat transfer systems Heat transfer between corrosive fluids Co-current heat transfer systems ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design In a multipass shell and tube heat exchanger, the baffles on shell side is primarily provided for Reducing scale deposition Increasing pressure drop Fixing the tubes Creating turbulence Reducing scale deposition Increasing pressure drop Fixing the tubes Creating turbulence ANSWER DOWNLOAD EXAMIANS APP