Refrigeration and Air Conditioning The coefficient of performance of Electrolux refrigerator is the ratio of Heat absorbed by the evaporator to the heat supplied by the gas burner Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator Heat supplied by the gas burner to the heat absorbed by the evaporator Heat absorbed by the evaporator to the heat supplied by the gas burner Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator Heat supplied by the gas burner to the heat absorbed by the evaporator ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Which of the following statement is correct for ammonia as a refrigerant? It reacts with copper and its alloys. It is toxic to mucous membranes. All of these It requires large displacement per TR compared to fluoro carbons. It reacts with copper and its alloys. It is toxic to mucous membranes. All of these It requires large displacement per TR compared to fluoro carbons. ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The operating pressure for refrigerating units using R-12 as a refrigerant is 2 bar 15 bar 30 bar 8 bar 2 bar 15 bar 30 bar 8 bar ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning A refrigerating system operating on reversed Brayton refrigeration cycle is used for maintaining 250 K. If the temperature at the end of constant pressure cooling is 300 K and rise in the temperature of air in the refrigerator is 50 K, then the net work of compression will be (assume air as working substance with Cp = 1 kJ/kg) 50 kJ/kg 125 kJ/kg 25 kJ/kg 100 kJ/kg 50 kJ/kg 125 kJ/kg 25 kJ/kg 100 kJ/kg ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The temperature of ammonia after compression in a vapour compression system is 20 to 50°C None of these 70 to 110°C 50 to 70°C 20 to 50°C None of these 70 to 110°C 50 to 70°C ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The vertical and uniformly spaced lines on a psychrometric chart indicates Dry bulb temperature Wet bulb temperature Specific humidity Dew point temperature Dry bulb temperature Wet bulb temperature Specific humidity Dew point temperature ANSWER DOWNLOAD EXAMIANS APP