Electrical Machines Short circuiting is caused in the armature winding due to grounding of two or more turns of the same coil. any of above. failure of insulation between two turns of coil. failure of insulation between two commutator bars. grounding of two or more turns of the same coil. any of above. failure of insulation between two turns of coil. failure of insulation between two commutator bars. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines We can apply source transformation to voltage source when a resistance is connected to it in 13 HP. 10 HP. 15 HP. 14 HP. 13 HP. 10 HP. 15 HP. 14 HP. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Cogging and crawling are phenomena associated with any of the above. cage induction machines and they are essentially the same. the former at a fraction of its rate speed and the latter during starting. the former during starting and the latter at a fraction of its rated speed. any of the above. cage induction machines and they are essentially the same. the former at a fraction of its rate speed and the latter during starting. the former during starting and the latter at a fraction of its rated speed. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Semi closed slots or totally closed slots are used in induction motors, essentially to improve starting torque increase pull out torque reduce magnetising current and improve power factor decrease starting torque improve starting torque increase pull out torque reduce magnetising current and improve power factor decrease starting torque ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Two synchronous generators operating in parallel 200 MW and 400 MW respectively. The drooping characteristics of their governors are identical as 4% from no load to full load. Consider the governors operating at 50Hz on no load. How will the machine share, if the load is 600 MW? generator 1 gets over load 230.7 MW and 369.23 MW respectively generator 2 gets over load 200 MW and 400MW respectively generator 1 gets over load 230.7 MW and 369.23 MW respectively generator 2 gets over load 200 MW and 400MW respectively ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines For a DC Shunt Motor having armature resistance of 0.5 Ω and 2 A armature current at no-load, when the armature current is changed to 20 A at loaded condition the speed is 1000 r.p.m. What is the speed at no-load? 1037.5 r.p.m. 1130 r.p.m. none of above. 4575.4 r.p.m. 1037.5 r.p.m. 1130 r.p.m. none of above. 4575.4 r.p.m. ANSWER DOWNLOAD EXAMIANS APP