DGVCL Exam Paper (11-12-2011) Rated making capacity of a ciruit breaker is equal to √2 X rated symmetrical breaking capacity Rated symmetrical breaking capacity 2.55 X rated symmetrical breaking capacity 1.11 X rated symmetrical breaking capacity √2 X rated symmetrical breaking capacity Rated symmetrical breaking capacity 2.55 X rated symmetrical breaking capacity 1.11 X rated symmetrical breaking capacity ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) It is difficult interrupt a capacitive current because Current magnitude is very small Stored energy in the capacitor is very high The restriking voltage can be high It has a leading power factor Current magnitude is very small Stored energy in the capacitor is very high The restriking voltage can be high It has a leading power factor ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Buchholz relay causes Tripping for major faults and alarm for minor faults Tripping for minor faults and alarm for major faults Alarm for both major and minor faults Tripping for both major and minor faults Tripping for major faults and alarm for minor faults Tripping for minor faults and alarm for major faults Alarm for both major and minor faults Tripping for both major and minor faults ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Bulk power transmission over long HVDC lines are preferred on account of Minimum line power losses Simple protection Low cost of HVDC terminals No harmonic problems Minimum line power losses Simple protection Low cost of HVDC terminals No harmonic problems ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) If a relay fails to operate inspite of a fault in its own zone of protection, it is said to Reach Under reach Pick up Over reach Reach Under reach Pick up Over reach ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) An IDMT relay provides An inverse characteristic for low values of the fault current and a definite time characteristic for high values of the fault current An inverse time current characteristic A definite time cuttent characteristic A definite time characteristic for low values of the failt current and an inverse characteristic for high values of the fault current An inverse characteristic for low values of the fault current and a definite time characteristic for high values of the fault current An inverse time current characteristic A definite time cuttent characteristic A definite time characteristic for low values of the failt current and an inverse characteristic for high values of the fault current ANSWER DOWNLOAD EXAMIANS APP