MGVCL Exam Paper (30-07-2021 Shift 3)
The short circuit current of a solar cell is

directly proportional to radiation intensity
changes logarithmically with radiation
constant and not affected by radiation
inversely proportional to radiation intensity

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 3)
Continuous and rapid variations in the load current magnitude which causes voltage variations is known as

Harmonics
Flicker
Voltage sag
Voltage distortion

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 3)
Consider the following statements and choose the correct option.
Statement 1: DVR (Dynamic Voltage Restorer) is a series compensation device.
Statement 2: DVR protects sensitive electric load from power quality problems such as voltage sags, swells, unbalance and distortion through power electronic controllers."
Statement 2: In a synchronous motor, at no-load condition, and with normal excitation the armature current

Both Statement 1 and Statement 2 are FALSE
Statement 1 is FALSE and Statement 2 is TRUE
Statement 1 is TRUE and Statement 2 is FALSE
Both Statement 1 and Statement 2 are TRUE

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 3)
The current flowing in to a balanced delta connected load through line 'a' is 10 A when the conductor of line ’b’ is open. With the current in line 'a' as reference, compute the symmetrical components of the line currents. Assume the phase sequence of ’abc’.

Ia₀ = 0 A.Ia₁ = (-1.66 + j2.88) A.Ia₂ = (1.66 + j2.88) A.
Ia₀ = 0 A.Ia₁ = (-5 + j2.88) A.Ia₂ = (5 - j2.88) A.
Ia₀ = 10 A.Ia₁ = (-5 + j2.44) A.Ia₂ = (5 - j2.44) A.
Ia₀ = 10 A.Ia₁ = (-1.66 + j2.88) A.Ia₂ = (1.66 + j2.88) A.

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 3)
The most commonly used method for the protection of three phase feeder is

Time graded protection
Differential protection
Reverse power protection
None of these

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP