Electrical Machines
In dc machines, 1. reactance voltage is proportional to armature current 2.reactance voltage is proportional to core length 3.reactance voltage is due to self-flux of the coil undergoing commutation 4. armature-cross flux is neutralized by interpolar flux 5. interpolarmmf is more than armature mmf in the interpolar zone From these, the correct answer is

 1, 2, 3, 4
 1, 3, 5
 1, 2, 5
 2, 3, 4

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
Two generators operating in parallel with rating 50MW and 100MW respectively. Both their respective governor settings are identical as 4%, consider same no load frequency. How will the machine share a common load of 100 MW

 any of the above
 50 MW and 50 MW respectively
 66.67 MW and 33.33 MW respectively
 33.33 MW and 66.67 MW respectively

ANSWER DOWNLOAD EXAMIANS APP