Refrigeration and Air Conditioning Efficiency of a Carnot engine is given as 80%. If the cycle direction be reversed, what will be the value of C.O.P. of reversed Carnot Cycle? 1.25 0.8 0.5 0.25 1.25 0.8 0.5 0.25 ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning A valve which maintains a constant degree of superheat at the end of the evaporator coil, is called Thermostatic expansion valve High side float valve Low side float valve Automatic expansion valve Thermostatic expansion valve High side float valve Low side float valve Automatic expansion valve ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The coefficient of performance of Electrolux refrigerator is the ratio of Heat supplied by the gas burner to the heat absorbed by the evaporator Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator Heat absorbed by the evaporator to the heat supplied by the gas burner Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner Heat supplied by the gas burner to the heat absorbed by the evaporator Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator Heat absorbed by the evaporator to the heat supplied by the gas burner Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In a saturated air-water vapour mixture, the Dry bulb temperature is higher than wet bulb temperature Dry bulb temperature is higher than dew point temperature Dry bulb, wet bulb and dew point temperature are same Dew point temperature is lower than wet bulb temperature Dry bulb temperature is higher than wet bulb temperature Dry bulb temperature is higher than dew point temperature Dry bulb, wet bulb and dew point temperature are same Dew point temperature is lower than wet bulb temperature ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning During sensible cooling of air, specific humidity Remains constant None of the listed here Decreases Increases Remains constant None of the listed here Decreases Increases ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The pressure at the outlet of a refrigerant compressor is called Discharge pressure Suction pressure Back pressure Critical pressure Discharge pressure Suction pressure Back pressure Critical pressure ANSWER DOWNLOAD EXAMIANS APP