Design of Masonry Structures Consider the following statements:A high lime content in a composite cement-lime mortar results in1. Slow hardening.2. Quick setting.3. Weaker mortar. 1 and 3 are correct 1 and 2 are correct 1, 2 and 3 are correct 2 and 3 are correct 1 and 3 are correct 1 and 2 are correct 1, 2 and 3 are correct 2 and 3 are correct ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures Assertion A : For eccentricity ratio exceeding 1/6, effective thickness of masonry will get reduced.Reason R : For eccentricity ratio exceeding 1/6, there will be tension on one side of the member.Select your answer according to the codes give below: Both A and R is true and R is not the correct explanation of A Both A and R is true and R is the correct explanation of A A is true but R is false A is false but R is true Both A and R is true and R is not the correct explanation of A Both A and R is true and R is the correct explanation of A A is true but R is false A is false but R is true ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures Where a structural component or a system is providing lateral support to five or more walls or columns, the lateral load to be resisted may be taken as __________ of the total vertical load on the most heavily loaded wall or column in the group 5 % 4 % 6 % 7 % 5 % 4 % 6 % 7 % ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures Assertion A : Lime based mortars give higher ratio of brickwork strength to mortar strength as compared to non-lime mortar.Reason R : Lime based mortars have lower bond strength as compared to non-lime mortars.Select your answer according to the codes given below: A is true but R is false Both A and R is true but R is not the correct explanation of A Both A and R is true and R is the correct explanation of A A is false but R is true A is true but R is false Both A and R is true but R is not the correct explanation of A Both A and R is true and R is the correct explanation of A A is false but R is true ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures The effective height of free standing non-load bearing wall and column respectively will be 1.0H and 1.0H 2.0H and 2.0H 1.5H and 1.5H 2.0H and 1.5H 1.0H and 1.0H 2.0H and 2.0H 1.5H and 1.5H 2.0H and 1.5H ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures A free standing brick wall 20 cm thick is subjected to a wind pressure of 75 kg/m². The maximum height of wall from stability consideration is 0.64 m 0.96 m 1.5 m 1.28 m 0.64 m 0.96 m 1.5 m 1.28 m ANSWER DOWNLOAD EXAMIANS APP