Measurement and Instrumentation A 150 V moving iron voltmeter of accuracy class 1-0 reads 75 V when used in a circuit under standard condition. The maximum possible percentage error in the reading is 1% 1.5% 2.5% 2% 1% 1.5% 2.5% 2% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation If two meters X and Y require 40 mA and 50 mA respectively, to give full scale deflection, then X is more sensitive. Y is more sensitive. It would not be possible to assess the sensitivity on the basis of the given data. Both X and Y are equally sensitive. X is more sensitive. Y is more sensitive. It would not be possible to assess the sensitivity on the basis of the given data. Both X and Y are equally sensitive. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation No eddy current and hysteresis losses occur in Electrostatic instruments PMMC instruments Moving iron instruments Electrodynamo meter instruments Electrostatic instruments PMMC instruments Moving iron instruments Electrodynamo meter instruments ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation Assertion (A) : It is always desirable to take the reading of an indicating instrument very close to the full scale reading. Reason (R) : Accuracy of an indicating instrument is maximum at the full scale deflection and error increases as reading comes closer to the beginning of the scale. A is false bur R is true A is true but R is false Both A and R are true and R is the correct explanation of A Both A and R are true but R is NOT the correct explanation of A A is false bur R is true A is true but R is false Both A and R are true and R is the correct explanation of A Both A and R are true but R is NOT the correct explanation of A ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation An induction meter can handle current upto 10 A 100 A 60 A 30 A 10 A 100 A 60 A 30 A ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A moving iron ammeter produces a full scale torque of 240 μNm with a deflection of 120° at a current of 10 A. The rate of change of self induction (μH/radian) of the instrument at full scale is 2.0 μH/radian. 114.6 μH/radian. 12.0 μH/radian. 4.8 μH/radian. 2.0 μH/radian. 114.6 μH/radian. 12.0 μH/radian. 4.8 μH/radian. ANSWER DOWNLOAD EXAMIANS APP